Summary
CPA3000 and CPA4000 is high performance Current Probe Amplifiers for the CP3000/CP4000 AC/DC current probes .The current probes covered in this manual are listed
| Parameters | Model | |||
| CP3050 | ||||
| Range | 5A/V 10A/V | |||
| Minimum measured current | 5mA | |||
| Noise (Bandwidth limitation 20MHz) | ≤500uArms | |||
| Coupling mode | AC,DC | |||
| Low frequency bandwidth of AC coupling(-3dB) | <7Hz | |||
| Maximum current (Decreases as frequency increases Figure 14~17) | Range | 10A/V | 5A/V | |
| DC continuous | 50A | 25A | ||
| RMS (Positive wave) | 35A | 17.7A | ||
| Peak value | 50A | 50A | ||
| Terminal load requirement | 50Ω | |||
| Delay | Current system | 15ns | ||
| BNC line 1m | 5ns | |||
| Maximum insulation wire voltage | 300V CAT I | |||
| Insertion impedance | Refer to Figure1 | |||